ELECTRONIC PACKING VENT MONITOR
Analyze your gas compressor packing cases
|
- OVERVIEW
- FEATURES & BENEFITS
- TECHNICAL INFO
- DOWNLOADS
| Instrument | |
|---|---|
| Media Compatibility | All gases and liquids compatible with 316 stainless steel |
| Process Connection |
|
| Accuracy |
±1% of reading, ±0.5% of full scale ±0.05 SFPS
All calibrations on NIST traceable flow stands |
| Repeatability | ±0.5% of reading |
| Flow Range | From 0 to 100 ft/sec velocity; flow range depends on pipe or tube tee area |
| Operating Pressure |
Tube tee ePV: 500 psig
Insertable ePV with compression fitting:
|
| Operating Temperature | Standard: - 40°F to 250°F |
| Materials of Construction | (Wetted parts) 316L stainless steel with Hastelloy C-22 thermowells |
| Transmitter/Electronics | |
|---|---|
| Enclosure | NEMA 4X, anodized aluminum |
| Operating Temperature | -40°F to 160°F |
| Output Signals |
|
| Input Power | 24 Vdc (21.5 Vdc to 30 Vdc); maximum 2.5 watts |
| Agency Approvals | |
|---|---|
| FM & FMC/ CE MARK: | Class I, Division 2, Groups A, B, C & D Class II, Divsion 2, Groups E, F & G Class III, T4 @ Ta = 71°C Type 4X |
| NEMA Enclosure | Nonincendive |